Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Clin Child Adolesc Psychol ; 53(2): 216-230, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38236707

RESUMEN

OBJECTIVE: Irritability, typically defined as a proneness to anger, particularly in response to frustration, falls at the intersection of emotion and disruptive behavior. Despite well-defined translational models, there are few convergent findings regarding the pathophysiology of irritability. Most studies utilize computer-based tasks to examine neural responses to frustration, with little work examining stress-related responding to frustration in social contexts. The present study is the first to utilize the novel Frustration Social Stressor for Adolescents (FSS-A) to examine associations between adolescent irritability and psychological and physiological responses to frustration. METHOD: The FSS-A was completed by a predominantly male, racially, ethnically, and socioeconomically diverse sample of 64 12- to 17-year-olds, who were originally recruited as children with varying levels of irritability. Current irritability was assessed using the Multidimensional Assessment Profiles-Temper Loss scale (MAP-TL-Youth). Adolescents rated state anger and anxiety before and after the FSS-A, and usable salivary cortisol data were collected from 43 participants. RESULTS: Higher MAP-TL-Youth scores were associated with greater increases in anger during the FSS-A, but not increases in anxiety, or alterations in cortisol. Pre-task state anger negatively predicted the slope of the rise in cortisol observed in anticipation of the FSS-A. CONCLUSIONS: Results provide support for unique associations between adolescent irritability and anger during, and in anticipation of, frustrating social interactions. Such findings lay a foundation for future work aimed at informing physiological models and intervention targets.


Asunto(s)
Ira , Ansiedad , Frustación , Hidrocortisona , Genio Irritable , Saliva , Humanos , Adolescente , Masculino , Femenino , Genio Irritable/fisiología , Ira/fisiología , Hidrocortisona/análisis , Hidrocortisona/metabolismo , Saliva/química , Ansiedad/psicología , Niño , Estrés Psicológico/psicología
2.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
3.
Am J Cardiol ; 205: 241-248, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37611417

RESUMEN

Symptoms of aortic stenosis (AS) are not proportional to its severity and patients with very severe AS (VSAS) remain asymptomatic for a long time. The appropriate time for intervention in patients with VSAS and the effects of transcatheter aortic valve implantation (TAVI) on left ventricular hypertrophy (LVH) remain debated. Our aim was to compare the procedural and 30-day outcomes of TAVI between patients with VSAS and patients with severe AS (SAS) and the changes in LVH. We selected patients with an aortic peak velocity ≥5 m/s (VSAS) and those with aortic peak velocity 4 to 5 m/s (SAS) treated with TAVI. Patients with reduced left ventricular ejection fraction (<45%) were excluded. The primary end point was the incidence of all-cause death at 30 days. The secondary end points included the 30-day incidence of cardiac death, cardiac rehospitalization, and stroke/transient ischemic attack and the changes in LVH from baseline to 30 days. A total of 102 patients in the VSAS group and 535 in the SAS group were included. Patients in the VSAS group had a thicker septal wall (p <0.001) and a higher Agaston score (p <0.001) and calcium volume (p = 0.007). No differences were observed regarding the primary and secondary clinical end points. However, patients with VSAS showed a significantly greater improvement in concentric LVH, although the prevalence of concentric LVH remained higher than in patients with SAS. TAVI in patients with VSAS showed similar procedural and clinical outcomes to patients with SAS and experienced a more pronounced improvement in the prevalence of concentric LVH.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Hipertrofia Ventricular Izquierda , Estenosis de la Válvula Aórtica/cirugía
4.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37532153

RESUMEN

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros
5.
Clin Neurophysiol ; 149: 1-8, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36841009

RESUMEN

OBJECTIVE: Children with attention deficit hyperactivity disorder (ADHD) show attenuated mean P3 component amplitudes compared to typically developing (TD) children. This finding may be the result of individual differences in P3 amplitudes, P3 latencies, and/or greater single trial variability (STV) in amplitude or latency, suggesting neural "noise." METHODS: Event related potentials (ERPs) from 75 children with ADHD and 29 TD children were recorded with electroencephalography (EEG). Caregivers provided ratings on child ADHD symptoms. Single-trial ERP amplitudes and latencies were extracted from the P3 component time window during a visual oddball task. Additionally, we computed individual-centered and trial-centered P3 amplitudes to account for inter-individual and inter-trial variability in the timing of the P3 peak. RESULTS: In line with prior research, greater ADHD symptom severity was associated with reduced mean P3 amplitude. This correlation was no longer significant after correcting for inter-trial differences in P3 latency. In contrast, greater ADHD symptom severity was associated with reduced STV in P3 amplitude. CONCLUSIONS: Our results suggest that attenuated average P3 amplitude in ADHD samples is due to a consistent reduction in strength of the neurophysiological signal at the single trial level, as well as increased inter-trial variability in the timing of P3 peak amplitudes. The traditional method of extracting P3 amplitudes based on a single time window for all trials may not adequately capture variability in P3 latencies associated with ADHD. SIGNIFICANCE: Inter- and intra-individual differences in brain signatures should be considered in models of neurobiological differences in neurodevelopmental samples.


Asunto(s)
Trastorno por Déficit de Atención con Hiperactividad , Niño , Humanos , Trastorno por Déficit de Atención con Hiperactividad/diagnóstico , Encéfalo , Electroencefalografía/métodos , Potenciales Relacionados con Evento P300/fisiología , Potenciales Evocados/fisiología , Tiempo de Reacción/fisiología
6.
J Cardiovasc Med (Hagerstown) ; 23(9): 615-622, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35994710

RESUMEN

AIMS: To investigate the impact of the right ventricle to pulmonary artery (RV-PA) coupling on the outcome of patients undergoing transcatheter aortic valve intervention (TAVI), and to describe changes in right ventricular function, pulmonary hypertension, and their ratio after TAVI. METHODS: Three hundred and seventy-seven patients from the Italian ClinicalService Project, who underwent TAVI between February 2011 and August 2020, were included. Tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio was retrospectively calculated as a surrogate of RV-PA coupling. The population was stratified according to TAPSE/PASP using a cut-off of 0.36 mm/mmHg derived from a receiving operating characteristic (ROC) curve. The primary end point was 6-month all-cause death. RESULTS: Compared with patients with a TAPSE/PASP ratio ≥0.36 mm/mmHg (81%), those with TAPSE/PASP ratio <0.36 mm/mmHg (19%) had more comorbidities and were more symptomatic.Moreover, they were more likely to receive general anesthesia and an old generation device. Device success was similar between the two groups. A TAPSE/PASP ratio <0.36 mm/mmHg was associated with a higher risk of all-cause death at 6-months (17.3% versus 5.3%; adjusted HR 2.66; P = 0.041). The prognostic impact of the TAPSE/PASP ratio was stronger than the impact of TAPSE and PASP as separate parameters and was independent of the surgical risk score. Both TAPSE, PASP, and their ratio improved from baseline to 1 month and 6 months after TAVI. CONCLUSIONS: A TAPSE/PASP ratio <0.36 mm/mmHg is strongly associated with an increased risk of mortality after TAVI. Providing a left ventricle unloading, TAVI is associated with improvement of both TAPSE, PASP, and their ratio.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Derecha , Ecocardiografía Doppler , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Pronóstico , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Derecha
7.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-35595675

RESUMEN

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Sch Psychol ; 37(2): 147-159, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35266770

RESUMEN

Among the many impacts of the Coronavirus disease (COVID-19) pandemic, one of the most dramatic was the immediate closure of in-person schooling in March/April 2020 when parents were faced with much greater responsibility in supporting their children's learning. Despite this, few studies have examined parents' own perspectives of this experience. The aims of this preliminary study were to (a) identify challenges, benefits, and useful strategies related to remote learning and (b) examine differences in findings across two countries, between parents of youth with and without attention-deficit/hyperactivity disorder (ADHD), and between parents of children and adolescents. To address these aims, parent responses to open-ended questions on the Home Adjustment to COVID-19 Scale (HACS; Becker, Breaux, et al., 2020) were examined across three studies conducted in the United States and Australia (N = 606, children: 68.5% male, ages 6-17 years). The challenges most frequently expressed by parents included the child's difficulty staying on task (23.8% of parents), lack of motivation (18.3%), remote learning factors (17.8%), and lack of social interaction (14.4%). The most frequently expressed strategy related to using routines and schedules (58.2%) and the biggest benefit was more family time (20.3%). Findings were largely consistent across countries, ADHD status, and age, with a few notable group differences. Given that the most common challenges involved child- (e.g., difficulties with staying on task and motivation), parent- (e.g., balancing remote learning with work responsibilities), and school- (e.g., remote instruction difficulties) related factors, there is a need for improved support across these systems going forward. (PsycInfo Database Record (c) 2022 APA, all rights reserved).


Asunto(s)
Trastorno por Déficit de Atención con Hiperactividad , COVID-19 , Adolescente , Niño , Femenino , Humanos , Masculino , Pandemias , Padres , SARS-CoV-2 , Estados Unidos
9.
Catheter Cardiovasc Interv ; 96(7): 1500-1508, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32644300

RESUMEN

AIMS: We aim at exploring whether severe chronic kidney disease (CKD) may modify the impact of acute kidney injury (AKI) post-transcatheter aortic valve implantation (TAVI) on early, mid, and long-term mortality. METHODS AND RESULTS: The analysis included 2,733 TAVI patients from the Italian Clinical Service Project. The population was stratified in four groups according to the presence of baseline severe CKD and postprocedural AKI. All-cause mortality was the primary end point. Postprocedural AKI is associated with an increased risk of early and mid-term mortality after TAVI regardless of baseline severe CKD. Preprocedural severe CKD is associated with an increased risk of long-term mortality after TAVI regardless of postprocedural AKI. No interaction between preprocedural severe CKD and postprocedural AKI was observed in predicting mortality at both 30-day (CKD: hazard ratio [HR] = 2.65, 95% confidence interval [CI] = 1.15-6.12; no-CKD: HR = 3.83, 95% CI = 2.23-6.58; Pint = .129) and 1-year (CKD: HR = 2.29, 95% CI = 1.37-3.82; no-CKD: HR = 2.47, 95% CI = 1.75-3.49; Pint = .386). Preprocedural severe CKD is an independent predictor of postprocedural AKI (HR = 2.17, 95% CI = 1.56-3.03; p < .001) as well as general anesthesia and access alternative to femoral. Among no-AKI patients, those with severe CKD at admission underwent kidney function recovery after TAVI (serum creatinine at baseline 2.24 ± 1.57 mg/dL and at 48-hr 1.80 ± 1.17 mg/dL; p = .003). CONCLUSIONS: Preprocedural severe CKD did not modify the impact of postprocedural AKI in predicting early and mid-term mortality after TAVI. Closely monitoring of serum creatinine and strategies to prevent AKI post-TAVI are needed also in patients without severe CKD at admission.


Asunto(s)
Lesión Renal Aguda/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Tasa de Filtración Glomerular , Riñón/fisiopatología , Insuficiencia Renal Crónica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Biomarcadores/sangre , Causas de Muerte , Creatinina/sangre , Femenino , Humanos , Italia/epidemiología , Masculino , Estudios Prospectivos , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/fisiopatología , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Eur Heart J ; 41(20): 1876-1886, 2020 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-31904800

RESUMEN

AIMS: In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). METHODS AND RESULTS: Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4-6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan-Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1-4.3%] and 1.6% (95% CI 0.6-3.9%), respectively, while late BVF was 2.5% (95% CI 1.2-5%). CONCLUSION: While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
11.
J Cardiovasc Med (Hagerstown) ; 17 Suppl 2: e144-e145, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25111774

RESUMEN

: A 51-year-old man was hospitalized for recurrence of acute coronary syndrome after few months. Coronary angiography during first hospitalization showed no significant coronary stenosis, while the second time, right coronary artery presented an expansion at the proximal segment. Optical coherence tomography documented a long fibroatheroma with an ulceration and residual white thrombus.


Asunto(s)
Síndrome Coronario Agudo/etiología , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Placa Aterosclerótica , Tomografía de Coherencia Óptica , Úlcera/diagnóstico por imagen , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/complicaciones , Stents Liberadores de Fármacos , Electrocardiografía , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/instrumentación , Valor Predictivo de las Pruebas , Recurrencia , Úlcera/complicaciones , Úlcera/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...